- Wide spectral output
- Fast response (<40ms)
- Long life
- High pulse rate
- High efficiency – low power
- Custom window filter
- IR absorption (NDIR) gas sensing
- Infrared spectroscopy
- Noninvasive glucose measurement
- Explosive gas detection systems
- Automobile engine control and exhaust monitoring
- Toxic emission systems
- Combustion efficiency and emission monitoring
Model | OIR-800 Fxx | ||
Spectral output |
F35
F84 FSA FSI FF3 (Please see the optical characteristic.)
|
||
Emitter surface area | 1.8x1.8mm | ||
Window Size | 2.5mm in diameter | ||
Package Type | TO-5 | ||
Parameter | Typical | Unit | Conditions |
Operating temperature | -40~100 | ℃ | |
Storage temperature | -40~100 | ℃ | |
Resistance | 22 | ohms | |
Drive voltage | 4.5 | Volt | For 420℃ |
Drive current | 100 | mA | For 4.5V |
Rising time | 30 | ms | |
Falling time | 10 | ms | |
Working temp | 420 | ℃ | max |
Life time | 40,000 | hrs | 2Hz, duty cycle 1:1, 4.5V |
Power Consumption | 450 | mW | @4.5V℃ in N2 |